✔ NICEIC Approved Contractor ✔ BS 7671 compliant reports ✔ CHAS Accredited
Trusted Commercial EICR Testing for Businesses in England
Commercial EICR and Fixed Wire Testing for UK Business Premises
A commercial EICR shows the safety condition of your fixed electrical wiring. Edison Compliance Ltd tests commercial buildings across the UK. Our specialists check circuits and list faults in their report. You receive a certificate to support your compliance duties.
NICEIC | NAPIT | CHAS | Nationwide coverage | Mon to Fri, 9am to 5pm
Fixed Wire Testing for Commercial Properties
Workers test lighting equipment during business hours across office spaces. Edison Compliance Ltd tests boards, circuits and fixed equipment. Our engineers record every result and rank each fault. You receive a clear report and an action list.

Distribution Board and Circuit Testing
We test every board, circuit and protective device. Results show where load, insulation or protection falls short.

Fixed Appliance & Installation Inspection
Technicians audit sockets, switches, fixtures, and fixed items. Staff log broken parts, wear, and unsafe connections.

Thermal Imaging & Fault Finding
Our cameras spot hot areas inside live boards and cables. We trace loose connections before they fail.

EICR Certification & Compliance
You receive a BS 7671 report with coded observations. The report supports your legal and insurance duties.
Request a Quote for Fixed Wire Testing
What Our EICR Commercial and Fixed Wire Testing Includes
Property layouts, loads, and risks shape EICR inspection cost. Our engineers follow BS 7671 and log results. We inspect and test circuits and boards. Reports cover our findings from all inspections. The stages below show what you receive.
Specialists evaluate distribution units and sub-boards. Teams evaluate power leads, toggles, power sockets, and machinery. Assessors identify faults, decay, heat stains, and threats. Staff check labels, covers, and protective units to build reports.
Dead testing measures continuity and insulation resistance with the supply isolated. Current checks polarity, earth fault loops, and RCDs. Tests expose hidden flaws in cables. Engineers record every reading in the report.
Specialists check circuits and controls. And plugs with thermal cameras. Infrared views expose component aging, heat marks, and risks. Staff record thermal pictures plus heat data points. Fix damaged sockets before system power failure occurs.
Standard BS 7671 tests power outlets. Specialists check indoor lighting fixtures. Logs feature C1, C2, C3, FI codes. Photos help explain findings when needed. The report states if the installation is satisfactory.
We rank each defect by urgency and recommend a repair. The plan helps you meet legal safety duties and insurer demands using thermal cameras. Our electricians complete the repairs if you instruct us. We issue confirmation of the completed work.
Signs You May Need a Commercial EICR
Faulty circuits display warning signs before causing system failure. Staff and facilities teams can spot many of these signs. Inform a qualified engineer about faulty boards without delay. Swift action protects employees, light fittings, and working times.

Frequent Circuit Breaker Tripping
Breaker or RCD trip cycles reveal active system overloads. Fuses that blow without extra load point to the same problem.

Flickering Lights & Power Surges
Damaged connections cause dimming across site lighting equipment. Rapid power shifts need engineer reviews during business hours.

Burning Smells or Discoloured Sockets
Burn marks show severe panel overheating. Workers spot discoloured plastic and odours. Staff isolate the circuit safely and phone site workers.

Overheating Distribution Boards
Warm distribution boards indicate loose electrical wiring faults. Infrared cameras find faulty lighting equipment for repair teams.

Ageing Electrical Installations
Systems reaching test dates need checks during business hours. Old wiring, damaged insulation, and outdated boards threaten workers.

Expired Inspection Certificate
Lapsed EICR documents strip away proof of wiring safety. Policy renewals, new tenants, and safety audits demand retests.
Why Choose Edison Compliance Services?
A reliable electrical compliance company protects your people and your premises. We test every system against British Standards on site. Our reports state each defect and its priority. Your facilities team knows what to fix first.
- One contractor for every need: Testing, safety and installation sit under one team.
- Clear reporting: Each report lists defects and recommended actions.
- Planned scheduling: We plan visits around your opening hours.
- Nationwide reach: Our Salford office supports sites across the UK.
- Accurate records: Every result sits in one clear report.
Facilities managers and landlords need records that satisfy auditors and insurers. Our certificates and reports meet that standard for every site. We store test data in a clear, consistent format. You find every result when an inspector asks.
Let’s Take Care of It!
Book your service quickly online or give us a call.
We’re ready when you are.